Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to
distribute optical signals from Central Office (CO) to multiple premise locations. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity. These are widely used in PON networks to realize optical signal power splitting as a low-cost solution.
Specifications
Parameter |
Unit |
Specification (P Grade) |
|||||||||
Channel No# |
1x2 |
1X3 |
1x4 |
1X6 |
1x8 |
1X12 |
1X16 |
1X24 |
1X32 |
1X64 |
|
Operation |
nm |
1260~1650 |
|||||||||
Insertion Loss |
dB |
4.3 |
6.2 |
7.4 |
9.8 |
10.7 |
12.5 |
13.9 |
16.5 |
17.2 |
21.5 |
Uniformity |
dB |
0.5 |
0.6 |
0.8 |
0.8 |
1.0 |
1.0 |
1.4 |
1.5 |
1.6 |
2.0 |
PDL |
dB |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.5 |
Return Loss |
dB |
50 |
|||||||||
Directivity |
dB |
50 |
Parameter |
Unit |
Specification (P Grade) |
|||||
Channel No# |
2X2 |
2X4 |
2X8 |
2X16 |
2X32 |
2X64 |
|
Operation |
nm |
1260~1650 |
|||||
Insertion Loss |
dB |
4.3 |
7.6 |
11.0 |
14.8 |
17.9 |
21.5 |
Uniformity |
dB |
0.8 |
1.0 |
1.2 |
1.5 |
1.8 |
2.5 |
PDL |
dB |
0.2 |
0.3 |
0.3 |
0.3 |
0.3 |
0.5 |
Return Loss |
dB |
50 |
|||||
Directivity |
dB |
50 |
Note: All the data above does not include connectors.
Feature
- Low PDL
- Low Insertion Loss
- High Returen Loss
- Compact Design
- Wide Operating Wavelength
- Wide Operating Temperature
- Uniform Power Splitting
Application
- FTTX(FTTP, FTTH, FTTN, FTTC)
- Local Area Networks (LAN)
- Passive Optical Networks (PON)
- Test Equipments